An image of the Spotlight Cam 4K Plus, mounted on an exterior wall of a house with the lights turned on.

Installing Spotlight Cam 4K Plus Wired

Download the user manual for Spotlight Cam 4K Plus Wired

Hardware included

An illustration of hardware items A through D, including caps, screws and a wire nut.


Tools needed

An illustration of a Phillips-head screwdriver.

Phillips-head screwdriver

An illustration of a caulk gun.

Caulk gun


WARNING: Electrical shock hazard. Disconnect power to installation area at your circuit breaker or fuse box before beginning installation. Always use caution when handling electrical wiring. Installation by a qualified electrician may be required in your area. Refer to your local laws and building codes before performing electrical work; permits plus professional installation may be required by law. Your Hardwire Kit must be installed on a 4“ round UL listed weatherproof electrical box when installed outdoors.

NOTE: If your power system is classified as OVC III, please check the building “Distribution Panel”, Ex switch panel has installed Surge Protectors. Ensure that the surge protector is a UL 1449 certified Surge Protector to reduce Mains Transient Voltage to Overvoltage Category II (2500 V pk or lower) before connecting to all AC Inputs. If there is no Surge Protector, do not install Hardwire Kit without one.

Before you begin installing your Hardwired Kit, make sure that you’re following safety code standards.


1.

Shut off power at the breaker.

An illustration of a circuit breaker panel with a warning symbol.

Junction boxes

For installing out-of-wall, 4-inch metal and plastic junction boxes:

Inspect your junction box before installing your Hardwired Kit. If you notice any signs of water ingress, pooling water, visible condensation, or rusted or corroded metal components, consult a qualified electrician in your area before proceeding with installation.


1.

For metal: Connect the green earth wires with junction box earth screw. (Home protective earthing and wired mount bonding conductor wires) See connection diagram. Then, connect the white (N) and black (L) wires with wire nuts.

Requires a minimum 14AWG or higher 3-core cable.

Optional: Temporarily install a machine screw to hold the S-hook for help connecting the wires. Remove the temporary screw after wires are connected.

If you can’t easily identify the wires coming out of your junction box, or have difficulty with or are uncomfortable connecting them, consult a licensed electrician.

An illustration of a metal junction box with an earth screw, cable clamp and wire connectors.

For plastic: Connect the green earth wires with a wire nut. (Home protective earthing and wired mount bonding conductor wires) See connection diagram. Then, connect the white (N) and black (L) wires with wire nuts.

NOTE: If you ever need to remove wires: Remove the white (N) and black (L) wires. Then, remove the wired mount bonding conductor wire and the home protective earthing conductor wire.

If you can’t easily identify the wires coming out of your junction box, or have difficulty with or are uncomfortable connecting them, consult a licensed electrician.

An illustration of a plastic junction box with cable clamp and wire connectors.

2.

For metal and plastic: Gently put the wires in the junction box and secure the wired mount to the junction box with 4 machine or tapping screws with O-rings.

An illustration of a wired mount being fastened to a junction box with a screwdriver and four screws.

3a.

For metal: Then, tighten the screws into the wired mount until the foam backing fully seals the junction box to prevent water from entering.

An illustration of a wired mount with four mounting screws and screw B highlighted.

3b.

For plastic: Tighten the screws into the wired mount until the foam backing fully seals the junction box to prevent water from entering.

An illustration of a wired mount with four mounting screws and screw D highlighted.

For in-wall and out-of-wall junction boxes:

4.

Apply a weatherproof silicone caulk or sealant around the outside where the wired mount and junction box or wall meet to prevent water from entering the junction box.

An illustration of a caulk gun applying sealant around the wired mount.

5.

Apply cosmetic screw plugs.

An illustration of the cosmetic screw plugs on a circular wired mount.

For installing in-wall, 3.5-inch plastic junction box and switch box:

1.

For junction and switch box: Attach the adapter plate to junction box with 2 tapping screws.

NOTE: If using a metal junction box, use screw C.

Requires a minimum 14AWG or higher 3-core cable.

An illustration of an adapter plate being secured to an in-wall junction box with screws.

2.

For junction and switch box: Connect the green earth wires with a wire nut. Then, connect the white (N) and black (L) wires with wire nuts.

NOTE: If you ever need to remove wires: Remove the white (N) and black (L) wires. Then, remove the wired mount bonding conductor wire and the home protective earthing conductor wire.

If you can’t easily identify the wires coming out of your junction box, or have difficulty with or are uncomfortable connecting them, consult a licensed electrician.

Optional: Temporarily install a machine screw to hold the S-hook for help connecting the wires. Remove the temporary screw after wires are connected.

An illustration of wires connected in an in-wall junction box with wire connectors.

3.

For junction and switch box: Stuff the wires gently into the junction box and screw the wired mount to the adapter plate with 4 machine screws with O-rings.

An illustration of a wired mount being fastened to the adapter plate on an in-wall box.

4.

For junction and switch box: Then, tighten the screws into the wired mount until the foam backing fully seals the junction box to prevent water from entering. (1.37-1.47N/m of torque force)

An illustration of a wired mount with four mounting screws and screw B highlighted.

For in-wall and out-of-wall junction boxes:

5.

Apply a weatherproof silicone caulk or sealant around the outside where the wired mount and junction box or wall meet to prevent water from entering the junction box.

An illustration of a caulk gun applying sealant around the wired mount.

6.

Apply cosmetic screw plugs.

An illustration of the cosmetic screw plugs on a circular wired mount.

Camera installation

1.

Tighten the included hex joint onto the back of your camera, ensuring the UP arrow is pointing up.

An illustration of a hex joint beside the camera and a screwdriver at its back.

2.

Remove the rubber plug from your camera’s power port.

NOTE: Store the rubber plug in a safe place. Reinsert it into the power port when not in use.

An illustration of a rubber plug being removed from the camera power port.

3.

Plug the USB-C cable on the junction box cover mount into your camera, ensuring it is fully inserted.

An illustration of a USB-C cable connecting the wired mount to the camera.

4.

Align the locking indicators on the hex joint and the junction box cover mount and insert.

An illustration of locking indicators aligned between the camera and wired mount.

5.

Turn until your camera locks in place.

An illustration of the camera turning on the wired mount to lock into place.

6.

Tighten the security screw.

An illustration of a screwdriver tightening a security screw beneath the mounted camera.

7.

Install your camera’s decorative cover by sliding until you hear a click to secure.

An illustration of a decorative cover sliding onto the mounted camera.

8.

Adjust your camera’s position, if necessary.

An illustration of the camera being adjusted within its circular mount.

9.

Apply a weatherproof silicone caulk or sealant around the junction box knockouts, between the junction box and junction box cover mount, and between the junction box and mounting surface to seal any gaps.

An illustration of a caulk gun applying sealant around the camera and wired mount.

10.

Restore power at the breaker.

An illustration of a circuit breaker panel with a warning symbol.

Last updated 3 days ago