Safety and compliance information for Ring Floodlight Cam Wired Pro

Failure to read and follow these safety instructions before operation could result in fire, electric shock, or other injury or damage.

WATCH FOR SMALL PARTS! Your device and accessories may present a choking hazard to small children. Keep them out of reach of small children.

WARNING: Electrical shock hazard! Disconnect power to installation area at your circuit breaker or fuse box before beginning installation. Always use caution when handling electrical wiring. Ring Floodlight Cam Wired Pro must be installed according to local electrical codes which might require that the Ring device be installed by a qualified electrician.

FIRE RISK! Do not mount near combustible or flammable surfaces.

SAFETY INFORMATION

The device is water resistant and is suitable for outdoor use. However, the device is not intended for underwater use. To protect against electric shock, do not submerge or immerse the device in water or expose the device or transformer to other liquids. Do not spill any food or beverages on the device. Do not attempt to clean or polish the device with or expose the device to oil, lotion, or other abrasive substances. Do not expose the device to salt water or other conductive liquids. Do not expose the device to pressurised water, high velocity water, or extremely humid conditions (such as a steam room). Do not attempt to dry the device with an external heat source, such as a microwave oven or a hair dryer. To avoid risk of electric shock, do not touch the device or any wires connected to the device during a lightning storm while the device is powered. If the device appears to be damaged, discontinue use immediately.

Do not install on the ground. Your device should be installed outdoors to a wall or eave. Do not cover the device while operating. Do not open the housing. Your device does not contain serviceable parts or replaceable LEDs. Protect this device from sunlight. Disconnecting the wires will power the device off. Do not use the device if the wires or housing are defective, there is a risk of electric shock. Do not cut any wires with factory installed wire connectors or remove the wire connectors. Do not install on circuits feeding motor loads such as kitchen appliances, HVAC equipment, washer / dryer or garage door openers. Do not install when it is raining. Do not stare directly at the LEDs for more than a few seconds to avoid eye injury.

Only use accessories that are recommended by the manufacturer. Use of third-party accessories may lead to damage to your device or the accessory and may cause fire, electric shock, or injury. Handle your device and its accessories with care. Your device or its accessories may have pointed edges which can lead to scratches, cuts, or other physical injury.

SAFELY CONNECTING THE RING FLOODLIGHT CAM WIRED PRO TO HOME ELECTRICAL WIRING

WARNING! You must disconnect the power source at the home’s circuit breaker or consumer unit and test that the power is off BEFORE removing an existing light fixture, installing the device, or touching electrical wires. It is extremely important to adhere to this safety precaution, especially if any natural gas, petrol fumes, or other potentially explosive fumes may be present in the vicinity. The provided screwdriver is not insulated. DO NOT USE if power has not been disconnected. Failure to turn off circuit breaker or consumer unit could result in EXPLOSION, FIRE, ELECTRIC SHOCK, DEATH, OTHER INJURY or PROPERTY DAMAGE.

BEFORE installing the device, review the diagrams and instructions provided. If the electrical wiring in the home does not resemble any of these diagrams or instructions, if you encounter damaged or unsafe wiring, or if you are unsure or uncomfortable in performing this installation or handling mains electrical wiring, please consult a qualified electrician. Verify that the supply voltage is correct. Connect fixture to a 100 VAC~240 VAC 50/60 Hz power source. You must ensure that you correctly identify Line, Neutral and Earth feeds from the home, and that these are installed in the correct terminals. If no Earth wire is present, DO NOT INSTALL. Contact a qualified electrician.

WARNING! Ensure the use of correct mounting hardware for the installation surface. If the included mounting hardware is not suitable, purchase suitable hardware.

More than one disconnect switch may be required to turn off power to the equipment before servicing. Perform safe isolation of the circuit before commencing installation. The disconnect device for this equipment shall be provided as part of the building installation and in a readily accessible location.

WARNING! Ensure all power cables are rated for the location they are in according to applicable local electrical code, and that mechanical protection is used to prevent the cable from becoming cut. Ensure cables are securely clamped to the bracket, but do not over tighten.

PRODUCT SPECIFICATIONS

Device name: Ring Floodlight Cam Wired Pro

Model number: 5B28S4

Dimensions: 32.6cm x 20.2cm x 21.7cm

Weight: 1.42kg

Maximum projected area: 100m2

Location: Outdoor use only

Maximum mounting height: 4.9m

Temperature rating: -20.5 °C to 48.0 °C

Electrical rating: 110-240V ~ 50/60Hz

Wireless features:

• Dual-Band wifi (2.4 & 5 GHz)

• Bluetooth

• Bluetooth Low Energy

Maximum equivalent isotropically radiated power:

2412 - 2472 MHz: 19.51 dBm EIRP

2402 - 2480 MHz: 11.11 dBm EIRP

5180 - 5700 MHz: 22.38 dBm EIRP

5725 - 5850 MHz: 13.53 dBm EIRP

This product contains a light source of energy efficiency class F.

DECLARATION OF CONFORMITY

Hereby, Ring LLC, declares that the radio equipment Ring Floodlight Cam Wired Pro (5B28S4) is in compliance with Directive 2014/53/EU and UK Radio Equipment Regulation, RER 2017 (S.I. 2017/1206), including currently valid amendment(s). The full texts of the declarations of conformity and other applicable statements of compliance for this product are available at the following internet address: www.ring.com/DoC

RADIO FREQUENCY COMPLIANCE

In order to protect human health, this device meets the thresholds for exposure of the general public to electromagnetic fields according to Council Recommendation 1999/519/EC. This device should be installed and operated with at least 20 cm between the radiator and your body.

This device is restricted to indoor use only when operating in the 5180 to 5350 MHz frequency range in the following countries: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Northern Ireland, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, and Turkey.

This device is restricted to indoor use only when operating in the 5150 to 5350 MHz frequency range in Great Britain.

RECYCLING YOUR DEVICE PROPERLY

In some areas, the disposal of certain electronic devices is regulated. Make sure you dispose of, or recycle, your device in accordance with your local laws and regulations. For information about recycling your device, go to amazon.com/devicesupport.

Click here to download the disassembly guide for recycling.

Energy efficiency information

Supplier’s name or trade mark: Ring

Supplier’s address: Ring, 1 Principal Place, Worship Street, London, EC2A 2FA

Model identifier: 5B28S4

Type of light source
Lighting technology used
LED
Non-directional or directional:
Directional
Light source cap-type (or other electric interface)
Soldered
Connected light source (CLS):
No
Mains or non-mains:
MLS
Envelope:
Non-clear
Colour-tuneable light source:
No
High luminance light source:
No
Anti-glare shield:
Yes
Dimmable:
Yes
General product parameters
Energy consumption in on-mode (kWh/1,000 h) rounded up to the nearest integer
24
Energy efficiency class
F
Useful luminous flux (Φuse), indicating if it refers to the flux in a sphere (360°), in a wide cone (120°) or in a narrow cone (90°)
2000 in wide cone
Correlated colour temperature, rounded to the nearest 100K, or the range of correlated colour temperatures, rounded to the nearest 100K, that can be set
3000K
On-mode power (Pon), expressed in W
23.5
Standby power (Psb), expressed in W and rounded to the second decimal point
0.48
Networked standby power (Pnet) for CLS, expressed in W and rounded to the second decimal point
N/A
Colour rendering index, rounded to the nearest integer, or the range of CRI-values that can be set
83
Outer dimensions without separate control gear, lighting control parts and non-lighting control parts, if any (millimetre)
Height
326
Width
217
Depth
197.5
Spectral power distribution in the range 250 nm to 800 nm, at full-load
Floodlight_Cam_Wired_Pro_power_distribution.png
Chromaticity coordinates (x and y)
X: 0.442
Y: 0.404
Parameters for directional light sources:
Peak luminous intensity (cd)
1059
Beam angle in degrees, or the range of beam angles that can be set
98
Parameters for LED and OLED light sources:
R9 colour rendering index value
9
Survival factor
-
The lumen maintenance factor
-
Parameters for LED and OLED mains light sources:
Displacement factor (cos φ1)
0.71
Colour consistency in McAdam ellipses
6
Flicker metric (Pst LM)
0.24
Stroboscopic effect metric (SVM)
0.003